To verify hardware status on FEX on Cisco Nexus Operating System.
show environment fex 100
Temperature Fex 100:
-----------------------------------------------------------------
Module Sensor MajorThresh MinorThres CurTemp Status
(Celsius) (Celsius) (Celsius)
-----------------------------------------------------------------
1 Outlet-1 92 89 42 ok
1 Outlet-2 76 68 38 ok
1 Inlet-1 61 53 37 ok
1 Die-1 92 85 48 ok
Fan Fex: 100:
------------------------------------------------------
Fan Model Hw Status
------------------------------------------------------
Chassis N2K-C2232-FAN -- ok
PS-1 N2200-PAC-400W -- failure
PS-2 N2200-PAC-400W -- ok
- show chassis routing-engine
- show chassis firmware – Verify jloader version
- Fdisk Command in Linux (Create Disk Partitions)
Power Supply Fex 100:
---------------------------------------------------------------------------
Voltage: 12 Volts
-----------------------------------------------------
PS Model Power Power Status
(Watts) (Amp)
-----------------------------------------------------
1 -- -- -- fail/shutdown
2 N2200-PAC-400W 396.00 33.00 ok
Mod Model Power Power Power Power Status
Requested Requested Allocated Allocated
(Watts) (Amp) (Watts) (Amp)
--- ------------------- ------- ---------- --------- ---------- ----------
1 N2K-C2232TM-10GE 102.00 8.50 102.00 8.50 powered-up
Power Usage Summary:
--------------------
Power Supply redundancy mode: redundant
Total Power Capacity 396.00 W
Power reserved for Supervisor(s) 102.00 W
Power currently used by Modules 0.00 W
-------------
Total Power Available 294.00 W
-------------
Pearl-N5K-02#